Solutions
A Solution is a choise in a special option Assessment.
Each solution can set individual variable values, which then can be used in the following formulas.
| Machinename | ID | Title | Published | Solution Type | Link to edit Solution | Condition | Variables |
|---|---|---|---|---|---|---|---|
| as_11 | 168 | Central heat generation system with gas boiler and radiators | On | Active systems | return v.as_generation == "G" && ['NA', 'R'].includes(v.as_emission) && v.as_technical_space == "Y" && ['NA', 'H'].includes(v.as_disturbance) && v.as_visibility == "I" | return { imp_fuel: "gas", imp_cop: 0.9 } |
|
| as_12 | 16 | Central heat generation system with gas boiler and wall heating | On | Active systems | return v.as_generation == "G" && ['NA', 'RW'].includes(v.as_emission) && v.as_technical_space == "Y" && ['NA', 'H'].includes(v.as_disturbance) && v.as_visibility == "N" | return { LCA_active: 16.73, RSL_active: 20, imp_fuel: "gas", imp_cop: 0.95 } |
|
| as_13 | 169 | Central heat generation system with geothermal heat pump and floor heating | On | Active systems | return v.as_generation == "HP" && ['NA', 'RF'].includes(v.as_emission) && v.as_technical_space == "Y" && ['NA', 'H'].includes(v.as_disturbance) && v.as_visibility == "N" && v.as_hp_temperature == "Y" && v.as_hp_electricity == "Y" && v.as_hp_space == "Y" | return { imp_fuel: "electricity", imp_cop: 5.88 } |
|
| as_14 | 170 | Central heat generation system with heat pump and ceiling heating | On | Active systems | return v.as_generation == "HP" && ['NA', 'RC'].includes(v.as_emission) && v.as_technical_space == "Y" && ['M', 'H', 'NA'].includes(v.as_disturbance) && v.as_visibility == "N" && v.as_hp_temperature == "Y" && v.as_hp_electricity == "Y" && v.as_hp_space == "Y" | return { imp_fuel: "electricity", imp_cop: 5.91 } |
|
| as_15 | 171 | Central heat generation system with heat pump and fans | On | Active systems | return v.as_generation == "HP" && ['NA', 'FC'].includes(v.as_emission) && v.as_technical_space == "Y" && ['M', 'H', 'NA'].includes(v.as_disturbance) && v.as_visibility == "I" && v.as_hp_temperature == "Y" && v.as_hp_electricity == "Y" && v.as_hp_space == "Y" | return { imp_fuel: "electricity", imp_cop: 4.1 } |
|
| as_16 | 17 | Central heat generation system with heat pump and floor heating | On | Active systems | return v.as_generation == "HP" && ['NA', 'RF'].includes(v.as_emission) && v.as_technical_space == "Y" && ['M', 'H', 'NA'].includes(v.as_disturbance) && v.as_visibility == "N" && v.as_hp_temperature == "Y" && v.as_hp_electricity == "Y" && v.as_hp_space == "Y" | return { LCA_active: 49.88, RSL_active: 20, imp_fuel: "electricity", imp_cop: 5.91 } |
|
| as_17 | 172 | Central heat generation system with oil boiler and floor heating | On | Active systems | return v.as_generation == "O" && ['NA', 'RF'].includes(v.as_emission) && v.as_technical_space == "Y" && v.as_visibility == "N" | return { imp_fuel: "oil", imp_cop: 0.9 } |
|
| as_18 | 173 | Centralized mechanical ventilation | On | Active systems | return v.as_generation == "E" && ['NA', 'FC'].includes(v.as_emission) && v.as_technical_space == "N" && ['NA', 'H'].includes(v.as_disturbance) && v.as_visibility == "N" | return { imp_fuel: "electricity", imp_cop: 1 } |
|
| as_19 | 174 | Centralized ventilation system | On | Active systems | return v.as_generation == "E" && ['NA', 'FC'].includes(v.as_emission) && v.as_technical_space == "Y" && ['M', 'H', 'NA'].includes(v.as_disturbance) && v.as_visibility == "N" | return { imp_fuel: "electricity", imp_cop: 1 } |
|
| as_2 | 161 | Boiler of pellet | On | Active systems | return v.as_generation == "W" && ['NA', 'RF'].includes(v.as_emission) && v.as_technical_space == "Y" && ['NA', 'H'].includes(v.as_disturbance) && v.as_visibility == "O" | return { imp_fuel: "biomass", imp_cop: 0.9 } |
|
| as_20 | 175 | Combined ventilation (natural + mechanical with heat recovery) | On | Active systems | return v.as_generation == "E" && ['NA', 'FC'].includes(v.as_emission) && v.as_technical_space == "N" && ['M', 'H', 'NA'].includes(v.as_disturbance) && v.as_visibility == "N" | return { imp_fuel: "electricity", imp_cop: 1 } |
|
| as_21 | 176 | Decentralized boiler for heating water | On | Active systems | return v.as_generation == "E" && ['NA', 'NA'].includes(v.as_emission) && v.as_technical_space == "Y" && v.as_visibility == "I" | return { imp_fuel: "electricity", imp_cop: 0.98 } |
|
| as_22 | 177 | Decentralized ventilation monoblocks | On | Active systems | return v.as_generation == "E" && ['NA', 'FC'].includes(v.as_emission) && v.as_technical_space == "N" && ['M', 'H', 'NA'].includes(v.as_disturbance) && v.as_visibility == "N" | return { imp_fuel: "electricity", imp_cop: 1 } |
|
| as_23 | 178 | Decentralized ventilation system | On | Active systems | return v.as_generation == "E" && ['NA', 'FC'].includes(v.as_emission) && v.as_technical_space == "N" && ['M', 'H', 'NA'].includes(v.as_disturbance) && v.as_visibility == "I" | return { imp_fuel: "electricity", imp_cop: 1 } |
|
| as_24 | 179 | District Heating Network with mixed heating | On | Active systems | return v.as_generation == "D" && ['NA', 'M'].includes(v.as_emission) && v.as_technical_space == "Y" && v.as_visibility == "I" | return { imp_fuel: "district_heating", imp_cop: 0.85 } |
|
| as_25 | 180 | District Heating Network with radiators | On | Active systems | return v.as_generation == "D" && ['NA', 'R'].includes(v.as_emission) && v.as_technical_space == "Y" && v.as_visibility == "I" | return { imp_fuel: "district_heating", imp_cop: 0.85 } |
|
| as_26 | 181 | District Heating Network with radiators (heating only) | On | Active systems | return v.as_generation == "D" && ['NA', 'R'].includes(v.as_emission) && v.as_technical_space == "Y" && v.as_visibility == "N" | return { imp_fuel: "district_heating", imp_cop: 0.85 } |
|
| as_27 | 182 | Electric heater with radiators | On | Active systems | return v.as_generation == "E" && ['NA', 'R'].includes(v.as_emission) && v.as_technical_space == "Y" && ['M', 'H', 'NA'].includes(v.as_disturbance) && v.as_visibility == "I" | return { imp_fuel: "electricity", imp_cop: 0.98 } |
|
| as_28 | 183 | Electric storage heating | On | Active systems | return v.as_generation == "E" && ['NA', 'R'].includes(v.as_emission) && v.as_technical_space == "N" && v.as_visibility == "I" | return { imp_fuel: "electricity", imp_cop: 0.98 } |
|
| as_29 | 184 | Electric wallpaper | On | Active systems | return v.as_generation == "E" && ['NA', 'RC'].includes(v.as_emission) && v.as_technical_space == "N" && v.as_visibility == "I" | return { imp_fuel: "electricity", imp_cop: 0.98 } |
|
| as_3 | 14 | Central heat generation system with boiler for biomass and ceiling heating | On | Active systems | return v.as_generation == "W" && ['NA', 'RC'].includes(v.as_emission) && v.as_technical_space == "Y" && ['M', 'H', 'NA'].includes(v.as_disturbance) && v.as_visibility == "N" | return { LCA_active: 29.51, RSL_active: 30, imp_fuel: "biomass", imp_cop: 0.9 } |
|
| as_30 | 185 | Electrical boiler with floor heating | On | Active systems | return v.as_generation == "E" && ['NA', 'RF'].includes(v.as_emission) && v.as_technical_space == "Y" && v.as_visibility == "N" | return { imp_fuel: "electricity", imp_cop: 0.98 } |
|
| as_31 | 186 | Ground heat pump | On | Active systems | return v.as_generation == "HP" && ['NA', 'RF'].includes(v.as_emission) && v.as_technical_space == "Y" && ['M', 'H', 'NA'].includes(v.as_disturbance) && v.as_visibility == "N" | return { imp_fuel: "electricity", imp_cop: 5.88 } |
|
| as_32 | 187 | Ground heat pump with mechanical ventilation | On | Active systems | return v.as_generation == "HP" && ['NA', 'RF'].includes(v.as_emission) && v.as_technical_space == "Y" && ['NA', 'H'].includes(v.as_disturbance) && v.as_visibility == "N" | return { imp_fuel: "electricity", imp_cop: 5.88 } |
|
| as_33 | 188 | Heat pump with mechanical ventilation | On | Active systems | return v.as_generation == "HP" && ['NA', 'R'].includes(v.as_emission) && v.as_technical_space == "Y" && ['M', 'H', 'NA'].includes(v.as_disturbance) && v.as_visibility == "O" | return { imp_fuel: "electricity", imp_cop: 4.08 } |